Pre-expanded cold shrink terminations and joints for 12/20kV MV networks, built around IEC dimensions for European and Middle East projects.

20kV cold shrink accessories are specified for 12/20kV systems -- the IEC voltage designation used across European utilities, Gulf-grid projects and most international EPC work. The parts follow the same pre-expanded, core-pull principle as the 15kV line, but are dimensioned and tested for the higher rated stress of a 20kV class network.
The buying decision here is usually made against a cable schedule and an IEC type-test requirement rather than a single catalogue number. RMU and switchgear OEMs, solar EPC contractors and utility distributors tend to qualify one body family across a conductor range and then manage stock by cable OD. We support that with an XLPE termination selector and consistent kit contents so a missing component never stops a joint on site.
| Voltage class | 12/20 kV (20 kV rated, IEC) |
| Cable range | 35 mm2 to 800 mm2 copper and aluminium XLPE |
| Sleeve material | EPDM / silicone with integrated stress cone |
| Operating temperature | -40 C to +90 C |
| Seal rating | IP68 after installation |
| Standards | IEC 60502-4, EN 50393, HD 629, GB/T 12706 |
| Installation | Cold shrink -- no heat source required |
On IEC 12/20kV systems the stress-control cone has to be right or partial discharge starts early in the joint life. A cold-shrink body carries that cone as a moulded feature, which removes the field-assembled step that heat-shrink and tape methods depend on. For EPC and OEM buyers the attraction is repeatability: the same body seats the same way regardless of which crew installs it, and there is no flame in a switchroom or cable basement.
The stress cone is fixed in the body, but the joint still needs correct cable preparation: screen cutoff length, semi-con finish and a clean weather seal. We size bodies by cable OD across the conductor range you carry, and pack each kit with the same component set so a termination and a straight joint on the same cable do not need two different orders.
The control plan for 20kV Cold Shrink Cable Accessories (12/20kV) is agreed with you. Batch traceability links the raw rubber lot through to the finished part and its test record.
For 8.7/15kV distribution feeders.
For 18/20kV mining and industrial duty.
For 26/35kV collector and substation duty.
The rated voltage class and the stress-control geometry. A 20kV (12/20kV IEC) body is tested for the higher system stress and will not substitute for a 15kV part on a 20kV network.
Yes. We provide an XLPE termination selector keyed to cable outer diameter and insulation type to simplify stock across a conductor range.
Yes. 20kV bodies are dimensioned for RMU and switchgear feeder terminations and tested to IEC 60502-4 / HD 629.
Each kit ships with a consistent component set for the cable range, reducing the risk of a missing seal or stress component during jointing.
No. Recovery is by core removal only; no torch or hot-air source is used.
Related reading on the selection and specification decisions behind 20kV Cold Shrink Cable Accessories (12/20kV).
Send the cable schedule (OD, insulation type, conductor range) and required IEC type-test status. We confirm the body family and lead time.