Pre-expanded silicone terminations and joints for 8.7/15kV MV networks. No heat, no open flame, installed by pulling the support core.
15kV cold shrink accessories cover 8.7/15kV medium-voltage cable terminations and straight joints for XLPE-insulated distribution and sub-transmission. Each part ships pre-expanded on a removable plastic core. On site you slide it over the prepared cable and pull the core; the rubber recovers by elastic memory and grips the jacket with constant radial pressure. There is no torch, no hot-air gun, and no skill-dependent heating step.
That matters on the jobs where these parts are actually used. Renewable collector systems, data-center MV switchrooms and urban utility spurs all share the same constraints: no open flame in confined spaces, inconsistent installer skill, and a hard requirement that the seal hold against moisture ingress for the life of the joint. The build integrates a stress-control layer and a factory-fitted seal, so the field outcome depends far less on who is holding the tool.
| Voltage class | 8.7/15 kV (15 kV rated) |
| Cable range | 25 mm2 to 630 mm2 copper and aluminium XLPE |
| Sleeve material | EPDM / silicone, integrated stress-control layer |
| Operating temperature | -40 C to +90 C (silicone variant to +130 C) |
| Seal rating | IP68 after installation |
| Standards | IEEE 404, IEC 60502-4, EN 50393, GB/T 12706 |
| Installation | Cold shrink -- no heat source required |
At 15kV the failure mode is partial discharge at the stress concentration where the insulation screen ends. A cold-shrink termination carries a factory-formed stress-control geometry, so you are not relying on the installer to tape or mould it in the field. Against heat-shrink, the advantage is the absence of a heat source: in a cable trench, a packed switchroom or an explosive-atmosphere site, that removes a real hazard and a real skill variable. The trade is material cost and a tighter fit to the specified cable OD.
Stress control is built into the tube, but the joint still depends on cable preparation. Confirm the insulation-screen cutoff length against the body, measure the cable outer diameter (not just the conductor size) for body selection, and check that the kit covers the full conductor range you stock. Verify the core pull direction and that no lubricant remains on the contact surfaces.
We state the control plan with you. Batch traceability links the raw rubber lot to the finished part and the test record.
Next voltage step for 12/20kV networks.
For extra-high-voltage collector and substation duty.
Pair with switchgear busbar insulation.
Bodies are selected by cable outer diameter and insulation type, typically 25 mm2 to 630 mm2 copper or aluminium XLPE. Send the cable OD and we confirm the body.
No. Cold shrink is recovered by removing the internal support core. No torch or hot-air source is used.
The stress-control layer is moulded into the termination body at manufacture, so field PD performance does not depend on installer taping.
IEEE 404 and IEC 60502-4 are the common reference points; EN 50393 and GB/T 12706 apply for European and Chinese projects.
Yes. EPDM and silicone versions are rated for outdoor and buried service; confirm UV and temperature class for the site.
Related technical articles that help specify this product.
Attach the cable schedule with outer diameters and annual volume. We confirm the body against your cable OD and insulation type, and respond with lead time and pricing.