PET (Mylar) bolt insulation sleeve dimensions from M6 to M36, including ANSI and DIN variants, with guidance on length and wall for flange isolation.
This page is the size reference for our PET (Mylar) bolt insulation sleeves used in flange isolation kits. Bolt holes on pipelines, tanks and valves rarely follow one standard, so we cut sleeves to the bolt you actually use -- the M-series metric sizes below, plus ANSI and DIN variants -- and to the full bolt length so the dielectric break is continuous from head to nut.
Dimensions are indicative for selection; the sleeve inner diameter is matched to the bolt shank, and wall is chosen for the dielectric and mechanical duty. For a kit, send the bolt callout (for example M20 x 90 DIN 931) and we cut and pack to count.
| Sizes covered | M6, M8, M10, M12, M16, M20, M24, M30, M36 |
| Standards | Metric M-series, ANSI, DIN variants |
| Wall thickness | Thin wall, selected by duty |
| Length | Cut to full bolt length, custom |
| Material | PET (Mylar) film tube |
| Purpose | Galvanic-corrosion and stray-current isolation |
| Supply | Loose sleeve or counted kit component |
A sleeve that is too short or the wrong diameter leaves the fastener touching the flange at one point, and that one contact defeats the whole isolation kit. Sizing the inner diameter to the bolt shank and the length to the full stud keeps the dielectric path continuous from the head to the nut. We hold wall thin enough to fit inside the nut clearance yet thick enough for the required dielectric strength.
State the bolt size, standard (M / ANSI / DIN) and overall length. For kits we cut to length and pack to the bolt count so assembly has no missing or misfit sleeves. Wall is selected against the dielectric requirement, not maximised.
We state the control plan with you. Batch traceability links the film lot to the finished sleeve and the inspection record.
Main product page and quotation.
Sleeves as part of isolation kits.
General PET film tubes.
M6 through M36 as standard, with ANSI and DIN variants; other sizes on request.
By the full bolt length from head to nut; send the bolt callout (size, standard, length).
PET for standard flange duty at lower cost; PTFE where temperature or chemical exposure is higher.
Yes, counted and packed to the bolt count for flange isolation kits.
The table is for selection; confirm the bolt callout and we cut to the required size.
Related technical articles that help specify this product.
Send the bolt callout (size, standard, length) and kit quantity. We cut and pack the sleeves to count.